On this page
Quick Start and Operation
Electronics & Noise Control
Common Noise Problems
Plasma cutting creates electrical interference that can cause random cut failures, THC glitches, or communication dropouts.
Best Practices
-
Ground everything: table, gantry, control box, and plasma power supply tied to a single earth ground.
-
Separate high-voltage and low-voltage lines. Never run torch leads alongside signal cables. Cross at 90° if necessary.
-
Use shielded cables for RS485 and USB connections.
-
Secure RS485 hub plugs — vibration loosens them over time.
-
Keep torch leads off the floor to reduce interference loops.
Troubleshooting
-
Random stops → check grounding and shielding first.
-
THC cutting out → reseat connections in the CandCNC hub.
-
Motion glitches → inspect motor/signal wiring for noise pickup.